Meiji Microscope Micrometers
- scroll down to order -
| Micrometers are commonly used for measuring or counting specimens. Eyepiece micrometers (also called reticles) are small glass discs with markings on them. The micrometer is mounted in one of the two eyepieces and superimposes an image of the markings over the image of the specimen. Stage micrometers are slides with markings of a known dimension that, when viewed under the microscope, can be used to calibrate eyepiece micrometers. |
|
Calibration: Since the size of the eyepiece micrometer image (e.g. a linear scale) appears the same even though the specimen can be magnified to a greater or lesser degree, the markings on the micrometer do not by themselves indicate any particular measurement. When a stage micrometer with known dimensions is viewed through an eyepiece micrometer, however, the measurement indicated by the eyepiece micrometer at that magnification can be noted and later used to make accurate measurements.
EYEPIECE MICROMETERS Dimensions given are the actual size of the markings on the micrometer disc. Eyepieces for our various models require micrometers of different diameter. The model numbers listed below refer to microscopes with standard 10x eyepieces. If you are using optional eyepieces of a different magnification and do not see them listed, contact us to find out the correct size.
25mm Diameter Micrometers for RZ Series 10x eyepieces, and all EM Series eyepieces MA523 Cross-line MA506 Linear scale, 10mm divided into 100 units MA509 Linear scale, 5mm divided into 100 units MA510 Counting grid, 10mm square divided into 100 1mm squares MA524 Counting grid, 10mm square divided into 400 0.5mm squares MA542 Cross-line with 0.01 mm graduations more below - |
|
|
21mm Diameter Micrometers for ML2000, ML5000, ML7000, ML7500, ML8000, and ML8500 Series 10x eyepieces - scroll down to order - |
|
|
MA284 MA255 MA256 MA283/05 MA540 MA254/05 |
Cross-line Linear scale, 10mm divided into 100 units Linear scale, 5mm divided into 100 units Counting grid, 10mm square divided into 100 1mm squares Cross-line with 0.01 mm graduations Walton & Beckett |
|
more below - 19mm Diameter Micrometers for RZ Series 15x and 20x eyepieces, and all TM200 and TM400 Series eyepieces MA279 Cross-line MA223 Linear scale, 0.5" divided into 50 units MA280 Linear scale, 10mm divided into 100 units MA281 Linear scale, 5mm divided into 100 units MA282 Counting grid, 10mm square divided into 400 0.5mm squares MA283 Counting grid, 10mm square divided into 100 1mm squares MA253 Cross-line with dotted lines MA539 Cross-line with 0.01 mm graduations MA254 Walton & Beckett more below - STAGE MICROMETERS
MA285 Linear scale, 1mm divided into 0.01mm units, for transmitted light MA292 Linear scale, 1mm divided into 0.01mm units, for reflected light MA286 Linear scale, 0.4" divided into 0.001" units, for transmitted light MA287 Counting grid, 0.2mm square divided into 400 .01mm squares, for transmitted light - scroll down to order - |
|
| EYEPIECE MICROMETERS OF (19MM) DIAMETER FOR USE WITH MA212, MA213, MA480, MA406, MA408, MA413 EYEPIECES | ||
|
MA171
|
Photo
framing reticle, 19mm diameter for HWF10X
|
|
|
MA223
|
0.50"
divided into 50 units, 19mm diameter
|
|
|
MA279
|
Cross-line
reticle, 19mm diameter
|
|
|
MA280
|
10mm
divided into 100 units, 19mm diameter
|
|
|
MA281
|
5mm
divided into 100 units, 19mm diameter
|
|
|
MA282
|
10mm
square into 400 parts, 0.5mm square, 19mm diameter
|
|
|
MA283
|
10mm
square into 100 parts, 1.0mm square, 19mm diameter
|
|
|
MA239
|
Cross-line
with 0.1 graduations, 19mm diameter
|
|
|
MA253
|
Cross-line
with dotted lines, 19mm diameter
|
|
|
MA254
|
Walton
& Beckett reticle, 19mm diameter
|
|
|
MA544
|
Photo
framing reticle for photomicrographic camera
|
|
|
EYEPIECES
MICROMETERS OF (21MM) DIAMTER FOR USE WITH MA407 KHW10X EYEPICE
|
||
|
MA284
|
Crossline
reticle, 21mm diameter
|
|
|
MA255
|
10mm
divided into 100 units, 21mm diameter
|
|
| MA256 | 5mm divided into 100 units, 21mm diameter | |
|
MA283/05
|
10mm
square into 100 parts, 1.0 mm square, 21mm diameter
|
|
|
MA540
|
Cross-line
with 0.1mm graduations, 21mm diameter
|
|
| MA254/05 | Walton & Beckett reticle, 21mm diameter | |
| EYEPIECE MICROMETERS OF (25MM) DIAMETER FOR USE WITH MA102, MA103, MA104, MA502, MA503, MA535, MA504, MA519 EYEPIECES | ||
|
MA523
|
Cross-line
with 25mm diameter
|
|
|
MA506
|
10mm
divided into 100 units, 25 mm diameter
|
|
|
MA509
|
5
mm divided into 100 units, 25 mm diameter
|
|
|
MA524
|
10mm
divided into 400 parts, 0.5mm square, 25 mm diameterr
|
|
|
MA510
|
10
mm quare into 100 units, 1.0 mm square, 25 mm diameter
|
|
|
MA542
|
Cross-line
with 0.1 mm graduation, 25mm diameter
|
|
|
MA541
|
Photo
framing reticle for SWF10X eyepiece
|
|
|
Stage
Micrometer
|
||
|
MA285
|
Linear
scale, 1mm divided into 0.01mm units, for transmitted light
|
|
|
MA286
|
Linear scale, 0.4" divided into 0.001" units, for transmitted light
|
|
|
MA287
|
Counting grid, 0.2mm square divided into 400 .01mm squares, for transmitted light - |
|
|
MA292
|
Linear
scale, 1mm divided into 0.01mm units, for reflected light
|
|
|
MA186
|
Stage
Micrometer for checking alignment of stereo microscopes
|
|
![]()
Statements quoted from MEIJI TECHNO AMERICA
![]() |
|||
|
|
|||
| | Mettler Electronics | | | X-Ray Equipments & Accessories | | | Sport Whirlpool | | | CPM | |
| | Diabetic Shoes | | | Muscle Stimulators, Electrodes | | | Ultrasound Gel | | | Microscope | |
| | Wheelchairs, Ramps | | | Walker, Bath, Toilet | | | Lead Wire & Adaptor | | | Lancet | |
| | Nasal Spray Pump | | | Nasal Atomizers | | | Nasal Spray Applicator | | |
|
|
|||
|
You
may order on-line here or call 415 - 924 - 0606 or Fax 215 - 895 - 9816
|
|
YinPo
Global Media, Inc. (YGM) , 159 Koch Road, Corte Madera CA 94925, USA
, www.YinPo.com
|
|
©
1997-2007 All Rights Reserved www.1-800-Medical.com, An Independent
Dealer
|
|
*********************************
|
|
|